<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Scientific Journal ASR-E-BARQ</title>
<title_fa>فصل نامه علمی عصر برق</title_fa>
<short_title>عصر برق</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://kiaeee.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2588-3828</journal_id_issn>
<journal_id_issn_online>2588-3828</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1401</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2023</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<volume>9</volume>
<number>18</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>امکان‌سنجی وقوع تشدید در خط ۴۰۰کیلوولت ابوطالب- تربت‌جام</title_fa>
	<title>Feasibility of Resonance in the 400 kV Abu Taleb-Torbat Jam Transmission line</title>
	<subject_fa>تخصصي</subject_fa>
	<subject>Special</subject>
	<content_type_fa>علمی- ترویجی</content_type_fa>
	<content_type>Scientific-extension</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:11pt&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Calibri&amp;quot;,&amp;quot;sans-serif&amp;quot;&quot;&gt;&lt;span lang=&quot;AR-SA&quot; style=&quot;font-family:&amp;quot;Arial&amp;quot;,&amp;quot;sans-serif&amp;quot;&quot;&gt;وقوع تشدید در خطوط انتقال می&#8204;تواند باعث ایجاد اضافه ولتاژهای نامتعارف شده و تجهیزات را در معرض خطر قرار دهد. یکی از شرایطی که می&#8204;تواند منجر به ایجاد تشدید در خطوط انتقال شود، وصل نامتقارن (تک&#8204;فاز و دوفاز) در خطوط انتقال جبران&#8204;سازی شده با راکتور موازی است. وصل نامتقارن خط می&#8204;تواند ناشی از عدم عملکرد فازهای کلید، فعال بودن ریکلوزر تک&#8204;فاز و یا وجود سوئیچ سنکرون در خط باشد. در این مقاله، امکان سنجی وقوع تشدید در خط&lt;/span&gt; kV &lt;span lang=&quot;AR-SA&quot; style=&quot;font-family:&amp;quot;Arial&amp;quot;,&amp;quot;sans-serif&amp;quot;&quot;&gt;400&lt;/span&gt; &lt;span lang=&quot;AR-SA&quot; style=&quot;font-family:&amp;quot;Arial&amp;quot;,&amp;quot;sans-serif&amp;quot;&quot;&gt;ابوطالب- تربت&#8204;جام با استفاده از نرمافزار&lt;/span&gt; EMTP-RV &lt;span lang=&quot;AR-SA&quot; style=&quot;font-family:&amp;quot;Arial&amp;quot;,&amp;quot;sans-serif&amp;quot;&quot;&gt;مورد بررسی قرار میگیرد. با توجه به نتایج بدست آمده در حالت وصل نامتقارن (تک&#8204;فاز و دوفاز) خط ابوطالب-تربت&#8204;جام، تشدید در فرکانس قدرت اتفاق نمی&#8204;افتد. اما این خط دارای فرکانس تشدید در محدوده&#8204;ی هارمونیک&#8204;ها است. برای بررسی تاثیر هارمونیک&#8204;ها، مطالعات&#8204; هارمونیکی انجام گرفته و نشان داده می&#8204;شود که هارمونیک&#8204;ها نمی&#8204;توانند اضافه ولتاژهای نامتعارف در این خط ایجاد نمایند&lt;/span&gt;.&lt;span style=&quot;font-family:&amp;quot;Arial&amp;quot;,&amp;quot;sans-serif&amp;quot;&quot; lang=&quot;AR-SA&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size:11pt&quot;&gt;&lt;span style=&quot;line-height:107%&quot;&gt;&lt;span style=&quot;font-family:&amp;quot;Calibri&amp;quot;,&amp;quot;sans-serif&amp;quot;&quot;&gt;&amp;nbsp;Resonance in transmission lines can cause unusual over-voltages and put the equipment at risk. One of conditions that can lead to resonance in transmission lines is the asymmetrical connection (single-phase and two-phase) of transmission lines compensated by shunt reactor. The asymmetrical connection of the line can be caused by the failure of the circuit breaker, activation of the single-phase recloser, or the presence of switchsync relay. In this paper, the feasibility of resonance in the &lt;span dir=&quot;RTL&quot; lang=&quot;AR-SA&quot; style=&quot;font-family:&amp;quot;Arial&amp;quot;,&amp;quot;sans-serif&amp;quot;&quot;&gt;400&lt;/span&gt; kV Abu Talib-Torbat Jam transmission line is investigated using EMTP-RV software. According to the results, in the case of asymmetrical connection (single-phase and two-phase) of the Abu Talib-Torbat Jam transmission line, resonance does not occur in the power frequency. But this line has a resonant frequency in the range of harmonics. In order to investigate the effect of harmonics, harmonic studies have been conducted and it is shown that harmonics cannot cause unusual over-voltages in this line.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;

&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;/div&gt;</abstract>
	<keyword_fa>تشدید, خط انتقال, راکتور موازی, وصل نامتقارن.</keyword_fa>
	<keyword>Resonance, Transmission line, Shunt reactor, Asymmetrical connection</keyword>
	<start_page>16</start_page>
	<end_page>21</end_page>
	<web_url>http://kiaeee.ir/browse.php?a_code=A-10-425-2&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Javad</first_name>
	<middle_name></middle_name>
	<last_name>Modarresi</last_name>
	<suffix></suffix>
	<first_name_fa>جواد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مدرسی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>j.modarresi@qiet.ac.ir</email>
	<code>10031947532846001041</code>
	<orcid>10031947532846001041</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>گروه مهندس برق، دانشگاه صنعتی قوچان</affiliation_fa>
	 </author>


	<author>
	<first_name>Ebadollah </first_name>
	<middle_name></middle_name>
	<last_name>Kamyab</last_name>
	<suffix></suffix>
	<first_name_fa>عباداله</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کامیاب</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>ebad.kamyab@gmail.com</email>
	<code>10031947532846001042</code>
	<orcid>10031947532846001042</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دفتر تحقیقات و کنترل کیفیت تجهیزات، شرکت برق منطقه‌ای خراسان</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
